PRODUCT CATEGORIES
Multi Drug Test Alco-Screen
Multi Drug Test BreathScan
Multi Drug Test QED A150
Multi Drug Test Oralert 6
Multi Drug Test Oratect III
Multi Drug Test OratectPlus
Multi Drug Test Oral Cube
Multi Drug Test CLIA Waived
Multi Drug Test Multi Test Cups
Multi Drug Test Rapid Detect Cards
Multi Drug Test Single Panel Dip Card
Multi Drug Test Multi Panel Dip Card
Multi Drug Test Multi-CLIN 11 Cassette
Multi Drug Test Noble Key Cup
Multi Drug Test Split Key Cup
Multi Drug Test Short Dated Mark Downs
Multi Drug Test Amphetamines
Multi Drug Test Barbiturates
Multi Drug Test Benzodiazepine
Multi Drug Test Buprenorphine
Multi Drug Test Cocaine
Multi Drug Test Ecstacy
Multi Drug Test Marijuana
Multi Drug Test Methadone
Multi Drug Test Methamphetamine
Multi Drug Test Morphine
Multi Drug Test Opiate
Multi Drug Test Oxycodone
Multi Drug Test Phencyclidine
Multi Drug Test Propoxyphene
Multi Drug Test Tricyclic Antidepressants
Multi Drug Test Acon Drug Test Procedure
Multi Drug Test Alco-Screen Procedure
Multi Drug Test Alco-Screen 02 Procedure
Multi Drug Test E-Z Key Cup Procedure
Multi Drug Test Multi-CLIN 11 Procedure
Multi Drug Test OraLert 6 Procedure
Multi Drug Test Oratect III Procedure
Multi Drug Test OratectPlus Procedure
Multi Drug Test Rapid Detect Procedure
Multi Drug Test Split Key Cup Procedure
Multi Drug Test MDT F.A.Q.
Multi Drug Test MDT News
Home > MDT Product Support > OraLert 6 Procedure
OraLert 6 Procedure
View Oralert 6

Oralert 6 Oral Saliva Screen

OraLert6 Oral Drug Screen Device

Test Procedure

acon_oralert 6

1

  • Remove cap.
  • Ensure reservoir is locked in testing position by turning counterclockwise as far as possible.
  • Insert Sponge Collector into Mouth

    2

    • Insert sponge end of collector into mouth.
    • Actively swab the inside of the mouth and tongue with sponge. As soon as the sponge softens slightly, gently press the sponge between the tongue and teeth to ensure complete saturation.
    • The sponge is saturated when no hard spots can be detected. Collect for a total of (3) minutes before removing sponge.

    acon oralert 6

    3

    • Insert collector into device as shown.
    • Push collector down into chamber.
    • Turn collector clockwise to lock into chamber.

    acon oralert 6

    4

    • Wait 9 minutes, remove collector from device and read results.

    acon oralert 6

    5

    • Secure cap back onto collection chamber.
    • Turn reservoir clockwise as far as possible to lock.
    • If results are positive, secure reservoir with tamper evident tape and send to laboratory for confirmation
    Oralert 6 Oral Fluid Screen Instructions